Parameter |
Nominal rating |
Maximum rating |
Steam consumption, t/h |
189 |
207.7 |
Steam parameters upstream condensate storage tank |
||
Pressure, MPa |
3.43 |
3.75 |
Temperature, °С |
285 |
285 |
Steam parameters upstream low-pressure cylinder |
||
Pressure, MPa |
0.203 |
0.23 |
Temperature, °С |
120 |
123.9 |
Humidity at the exit from the low-pressure cylinder, % |
0.86 |
|
Power at generator terminals, MW |
36.5 |
40.3 |
Low-pressure turbine
Name of parameter |
Value* |
|
LP turbine operating mode |
Rated |
Maximum |
LP turbine steam consumption at, t/h |
152.4 |
172.8 |
LP turbine parameters of steam upstream: |
||
- pressure, MPa |
0.203 |
0.23 |
- temperature, 0С |
120 |
123.9 |
- intake humidity, % |
0.8-1.2 |
|
LP turbine electrical capacity, MW |
18 |
20.5 |
* in accordance with the technical specification issued by the Customer