LPT-17

Main characteristics of the marine type turbine unit

Parameter

Nominal rating

Maximum rating

Steam consumption, t/h

189

207.7

Steam parameters upstream condensate storage tank

Pressure, MPa

3.43

3.75

Temperature, °С

285

285

Steam parameters upstream low-pressure cylinder

Pressure, MPa

0.203

0.23

Temperature, °С

120

123.9

Humidity at the exit from the low-pressure cylinder, %

0.86

Power at generator terminals, MW

36.5

40.3

















Low-pressure turbine

Name of parameter

Value*

LP turbine operating mode

Rated

Maximum

LP turbine steam consumption at, t/h

152.4

172.8

LP turbine parameters of steam upstream:

- pressure, MPa

0.203

0.23

- temperature, 0С

120

123.9

- intake humidity, %

0.8-1.2

LP turbine electrical capacity, MW

18

20.5

* in accordance with the technical specification issued by the Customer