Steam turbines

Classification of steam turbines for CHP
5
10
15
20
25
Давление свежего пара, МПа
50
100
150
200
250
300
350
Мощность, МВт

Class М.1: single-casing turbines with straightsteam flow arrangement for pressure from 2.0 to 4.5 MPa (20-45 kgf/cm2), capacity range is from 5 to 16 MW. The turbine is assumed with both the radial exhaust to one water-cooled condenser and the axial exhaust to the air cooling condensing unit. The turbine is installed on a single frame and delivered as single-module assembly. The turbine features the possibility to organize single-stage controlled heat extraction with a capacity of up to 20 Gcal/h, as well as uncontrolled industrial steam bleeding for auxiliaries with a capacity of up to 40 t/h.

Characteristics

Values

Main type of the turbine

Cogeneration/ condensing

Basic design feature

Single-casing with a straight steam flow; the turbine is mounted on a single frame and shipped in a single module assembly

Steam distribution type

Throttle

Exhaust casing type

Radial/axial

Electricity output range, MW

5-16

Main steam characteristics:

- Pressure, MPa

2.0-4.5

- Temperature, °С

250-450

Capability of steam bleeding for heating:

- Scheme

Non-controlled steam bleeding; Single-stage delivery water heating

- Maximum heating load, Gcal/h

20

- Steam extraction flow rate, t/h

up to 40

Characteristics of the main condenser

- Cooling water flow rate, m3/h

1,000-5,500

- Heat exchange surface area, m2

800-2,500