Class М.1: single-casing turbines with straightsteam flow arrangement for pressure from 2.0 to 4.5 MPa (20-45 kgf/cm2), capacity range is from 5 to 16 MW. The turbine is assumed with both the radial exhaust to one water-cooled condenser and the axial exhaust to the air cooling condensing unit. The turbine is installed on a single frame and delivered as single-module assembly. The turbine features the possibility to organize single-stage controlled heat extraction with a capacity of up to 20 Gcal/h, as well as uncontrolled industrial steam bleeding for auxiliaries with a capacity of up to 40 t/h.
Characteristics |
Values |
Main type of the turbine |
Cogeneration/ condensing |
Basic design feature |
Single-casing with a straight steam flow; the turbine is mounted on a single frame and shipped in a single module assembly |
Steam distribution type |
Throttle |
Exhaust casing type |
Radial/axial |
Electricity output range, MW |
5-16 |
Main steam characteristics: |
|
- Pressure, MPa |
2.0-4.5 |
- Temperature, °С |
250-450 |
Capability of steam bleeding for heating: |
|
- Scheme |
Non-controlled steam bleeding; Single-stage delivery water heating |
- Maximum heating load, Gcal/h |
20 |
- Steam extraction flow rate, t/h |
up to 40 |
Characteristics of the main condenser |
|
- Cooling water flow rate, m3/h |
1,000-5,500 |
- Heat exchange surface area, m2 |
800-2,500 |